Sunday, 1 November 2026
Standing Office 81 (SOVNPA 81) emblem Viet Nam NVietnam National Presiding Agency
on Countering the Proliferation of Weapons of Mass Destruction
Standing Office 81

6A006"Magnetometers", "magnetic gradiometers", "intrinsic magnetic gradiometers", underwater electric field sensors, "compensation systems", and specially designed components therefor, as follows:

List
EU dual-use list – Annex I to Regulation (EU) 2021/821, updated annually
Originating regime
Thỏa ước Wassenaar
N.B. SEE ALSO 7A103.d.
Note:
6A006 does not control instruments specially designed for fishery applications or biomagnetic measurements for medical diagnostics.
a. "Magnetometers" and subsystems as follows:
1. "Magnetometers" using "superconductive" (SQUID) "technology" and having any of the following:
a. SQUID systems designed for stationary operation, without specially designed subsystems designed to reduce in-motion noise, and having a 'sensitivity' equal to or less (better) than 50 fT (rms) per square root Hz at a frequency of 1 Hz; or
b. SQUID systems having an in-motion-magnetometer 'sensitivity' less (better) than 20 pT (rms) per square root Hz at a frequency of 1 Hz and specially designed to reduce in-motion noise;
2. "Magnetometers" using optically pumped or nuclear precession (proton/Overhauser) "technology" having a 'sensitivity' less (better) than 20 pT (rms) per square root Hz at a frequency of 1 Hz;
3. "Magnetometers" using fluxgate "technology" having a 'sensitivity' equal to or less (better) than 10 pT (rms) per square root Hz at a frequency of 1 Hz;
4. Induction coil "magnetometers" having a 'sensitivity' less (better) than any of the following:
a. 0,05 nT (rms) per square root Hz at frequencies of less than 1 Hz;
b. 1 × 10-3 nT (rms) per square root Hz at frequencies of 1 Hz or more but not exceeding 10 Hz; or
c. 1 × 10-4 nT (rms) per square root Hz at frequencies exceeding 10 Hz;
5. Fibre optic "magnetometers" having a 'sensitivity' less (better) than 1 nT (rms) per square root Hz;
b. Underwater electric field sensors having a 'sensitivity' less (better) than 8 nanovolt per metre per square root Hz when measured at 1 Hz;
c. "Magnetic gradiometers" as follows:
1. "Magnetic gradiometers" using multiple "magnetometers" specified in 6A006.a.;
2. Fibre optic "intrinsic magnetic gradiometers" having a magnetic gradient field 'sensitivity' less (better) than 0,3 nT/m rms per square root Hz;
3. "Intrinsic magnetic gradiometers", using "technology" other than fibre-optic "technology", having a magnetic gradient field 'sensitivity' less (better) than 0,015 nT/m rms per square root Hz;
d. "Compensation systems" for magnetic or underwater electric field sensors resulting in a performance equal to or better than the specified parameters of 6A006.a., 6A006.b. or 6A006.c.;
e. Underwater electromagnetic receivers incorporating magnetic field sensors specified in 6A006.a. or underwater electric field sensors specified in 6A006.b.
Technical Note:
For the purposes of 6A006, 'sensitivity' (noise level) is the root mean square of the device-limited noise floor which is the lowest signal that can be measured.