- List
- Wassenaar Arrangement – List of Dual-Use Goods and Technologies – WA-LIST (25) 1
- Corresponding EU entry
- 9A002
a. Maximum continuous power when operating in "steady state mode" at standard reference conditions specified in ISO 3977-2:1997 (or national equivalent) of 24,245 kW or more; and
b. 'Corrected specific fuel consumption' not exceeding 0.219 kg/kWh at 35% of the maximum continuous power when using liquid fuel.
Note The term 'marine gas turbine engines' includes those industrial, or aero-derivative, gas turbine engines adapted for a ship's electric power generation or propulsion.
Technical Note
For the purposes of 9.A.2., 'corrected specific fuel consumption' is the specific fuel consumption of the engine corrected to a marine distillate liquid fuel having a net specific energy (i.e., net heating value) of 42MJ/kg (ISO 3977-2:1997).
b. 'Corrected specific fuel consumption' not exceeding 0.219 kg/kWh at 35% of the maximum continuous power when using liquid fuel.
Note The term 'marine gas turbine engines' includes those industrial, or aero-derivative, gas turbine engines adapted for a ship's electric power generation or propulsion.
Technical Note
For the purposes of 9.A.2., 'corrected specific fuel consumption' is the specific fuel consumption of the engine corrected to a marine distillate liquid fuel having a net specific energy (i.e., net heating value) of 42MJ/kg (ISO 3977-2:1997).